| Management number | 221441143 | Release Date | 2026/05/03 | List Price | US$27.84 | Model Number | 221441143 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
Relays / Current Monitoring RelaysFeaturesSuper SmallOver-Current Circuit Breaker Lock Separate Set-up for each Operation Delay / Operation Delay TimeWide Range of Set-upWide Operating Voltage RangeOperation Indicator and Identification of Actual Current(LED)Manual / Electric ResetAmbient InsensitiveLow Energy Consumption(No Volt Release/Fail-safe Operation)N TypeSingle-phase, three-phase available (No Volt Release/Fail-safe Operation)NUsed for- Low Voltage Induced Electromotor (600V Level) Protective Relay- Break-Down Watch Current Relay- Alternative Replacement for the Existing RelayProtetcionProtective Item Operating (Trip) TimeOver-Current = O-TIMEPhase Loss = O-TIMELocked Rotor = D-TIME+O-TIMELEDAmmeter Function:After the motor runs smoothly, turn the overcurrent setting slowly counter clockwise to the red indicator light, which is 100% of the actual running current. And then turn the clockwise to just turn off the red light at this point for the actual running current value of about 103%. Run / Operation Indicator:Relay Trip: Red LEDPower / normal operating status: Green LEDManual / Electric ResetWith test button held down,the red LED is on and the product will trip after O-TIME.The relay will be de-energized when RESET button is pushed or the control power is disconnected.SetAfter the installation is complete the as follows.Set : D-TIME(Delay Time) Set two to three seconds longer than the motor starting time.Set : O-TIME(Over-current run time) Set less than the motor's endurance time with over-current.Set Load(Rated Current) Set over 110% of the motor's rated current of under 120% of its operating current.TEST InstructionWith test button ehld down,the red LED is on and the product will trip after O-TIME.The relay will be de-energized when RESET button is pushed or the control power is disconnected.LED IndicationItem PWR(Green)LED Trip(Red)LEDSpecificationsCurrent Range............ : Type05) 1-6.5AType30) 5-30AType60) 5-60AType120) 10-120aType600) Use an external CT(secondary 5A)over 60A with 05 type.Operating Voltage(Un).: Tpye110) 110VACTpye220) 90-260VACTpye380) 180-460VACOperating Frequency....: 50/60Hz<;2WOperating Temperature: -20.....+55Waiting(t)......................: D-Time 0.2-60sO-Time 0.2-12sAsymmetry Set.............: %±10Contact.........................: 5A 250VAC Resistive LoadConnection Diagrams..: 35mm (D) or Theory : Thermal Relayis_customized : YesContact Load : Low PowerModel Number : SOPR-SS3-220Voltage : 220VUse : ProtectiveFeature : SealedOperating Voltage(Un) : 90-260VAC 50/60HzCurrent Range(A) : 0.5-6A / 3-30A / 5-60A / 10-120AMain Circuit Wiring : Through CoreRelay output : 1cProtected object : motorModel : EOCR/SOPR/DPR/EOPR
| Model | NSXVIG |
|---|---|
| Brand Name | NSXVIG |
| Part Number | NSXVIG |
| Contact Type | Normally Closed |
| Manufacturer | NSXVIG |
| Mounting Type | Chassis Mount |
| Connector Type | Clamp |
| Current Rating | 0.01 Amps |
| Contact Material | Aluminum |
| Specification Met | UL |
| Contact Current Rating | 1 Amps |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form